Circulator pump

Calio Therm

Stainless steel pump for drinking water circulation

High-efficiency wet rotor circulator pump for drinking and domestic water systems. With its stainless steel casing, it is used in buildings that need hot water circulation, such as homes, hotels and hospitals. Infinitely variable differential pressure control and an integrated display show the operating status at all times.

Connection
G 1½, G 2 and DN 40
Head
8 to 12 m
Available options
5
  • Suitable for drinking water
ACS approved
ACS approvedApproved in accordance with French drinking water regulations.C23A_5076192267-1_0
View Models

From union to flange

Options range from G 1½ and G 2 threaded models to DN 40 flanged models, with heads from 8 to 12 m and flow rates up to 24 m³/h. The maintenance-free design runs trouble-free for many years.

Why Calio Therm?

  1. 01

    Stainless Steel Casing

    Stainless steel casing that resists the corrosive effects of drinking and domestic water.

  2. 02

    Suitable for Drinking Water

    Developed for drinking water and domestic hot water circulation systems.

  3. 03

    Infinitely Variable Differential Pressure Control

    Efficient, demand-driven operation with variable speed and infinitely variable differential pressure control.

  4. 04

    Integrated Display

    The operating status can be monitored at any time via the display and symbols.

  5. 05

    Heads up to 12 m

    Sufficient head for hot water circuits in large buildings.

  6. 06

    Maintenance-Free

    Maintenance-free, long-life operation thanks to the wet rotor design.

Calio Therm technical data

Casing material
Stainless steel 1.4308
Operating modes
Constant pressure (p-c), variable pressure (p-v), Eco mode, Boost mode
External control
0-10 V, Modbus
Display
with display
Pressure rating
PN 6, PN 10
Temperature class
TF 110

Pump characteristic curves

The curves are taken from the type series booklet. Each chart shows the head (H) at the top and the power input (P1) at the bottom, with the flow rate (Q) on the horizontal axis. Select a model to see its curves, technical data and dimensions.

G 1½
G 2
DN 40

Technical details

Operating data
PropertyCalioTherm Pro
Flow rateUp to 24 m³/h
HeadUp to 12 m
Fluid temperature+2 to +70 °C (briefly up to +75 °C for max. 5 minutes)
Water hardnessMax. 20 °dH (35.7 °fH)
Ambient temperature0 to +40 °C
Operating pressureUp to 10 bar
Pressure ratingPN 6/10
Sound pressure levelMax. 40 dB(A)
Threaded connectionG 1½ and G 2
Flanged connectionDN 40

To prevent limescale, limiting the fluid temperature to 65 °C is recommended. Brief higher temperatures, e.g. for thermal disinfection, are permitted.

Technical data

All models run on 1~230 V AC, 50/60 Hz. On threaded models the pipe is connected with pipe unions available as accessories.

ModelPump connectionPipe connectionPNSpeed (rpm)Power input P1 (W)Current (A)Weight (kg)Material no.
25-80G 1½R 16/101000 - 40003.5 - 1800.15 - 0.864.629134853
30-100G 2R 1¼6/101000 - 45003.5 - 1800.15 - 0.854.829134854
30-120G 2R 1¼6/101000 - 40003.5 - 3300.15 - 1.506.429134855
40-80DN 40DN 406/101000 - 36003.5 - 2650.15 - 1.2211.129134849
40-100DN 40DN 406/101000 - 40003.5 - 3600.15 - 1.6511.129134856
Motor and design
  • Maintenance-free, glandless high-efficiency wet rotor pump
  • Brushless, self-cooling permanent magnet synchronous motor with continuously variable differential pressure control
  • 1~230 V AC (±10%), 50/60 Hz
  • Enclosure IPX4D, thermal class F, temperature class TF 110
  • Product-lubricated special plain bearing, integrated motor protection
  • Electromagnetic compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3
  • All wetted parts are approved for drinking water circulation systems; French drinking water approval (ACS)
Operating modes and functions

Operating modes

  • Constant pressure control (Δp-c)
  • Proportional pressure control (Δp-v)
  • Eco-Mode
  • Constant speed operation with a setpoint (open-loop control)
  • Temperature-dependent differential pressure control (activated via KSB ServiceTool only)

Automatic functions

  • Continuously variable speed adjustment according to the operating mode
  • Dynamic Control
  • External differential pressure setpoint or speed via 0-10 V signal
  • 0-10 V input for actual temperature or differential pressure value
  • Twin pump operation
  • High flow demand mode
  • Night setback
  • Remote on/off
  • Deblocking, self-venting of the pump casing, soft start
  • Full motor protection with integrated trip electronics

Manual settings

  • Operating mode
  • Head setpoint
  • Speed level
  • Keypad lock

Display and signals

  • The display alternates between flow rate, head and power input
  • Operating status and error code on the display
  • Configurable general fault and run signal (volt-free contact)
  • Modbus RTU serial digital interface
  • Service interface for KSB ServiceTool
Eco-Mode and Dynamic Control

Eco-Mode

In Eco-Mode the pump follows a quadratic curve: starting from the set head (HS), the curve drops to a quarter of that value at zero flow (H0 = 1/4 × HS). Power consumption is about 40% lower than with proportional pressure control. Changing the setpoint adapts the curve to a higher or lower pressure.

Dynamic Control

Dynamic Control detects when the selected control curve is higher than the building needs and shifts it down automatically, reducing power consumption. When the minimum curve that still ensures adequate supply is reached, the pump switches back to a higher curve. The pump therefore runs at the best point even when the system curve is unknown, flow noise at thermostatic valves is reduced and up to 40% additional energy is saved compared with proportional pressure control.

Applications and fluids

Applications

  • Drinking water circulation systems to DVGW W 551

Suitable fluids

  • Drinking water (TrinkwV 2001)
Materials
PartMaterial
Volute casing (102)Stainless steel 1.4308
Shaft (210)Stainless steel 1.4034
Impeller (230)Glass fibre reinforced plastic (PSU-GF30)
Bearing (310)Ceramic / carbon
Thermal insulation shell (689)Polypropylene
Can (817)Glass fibre reinforced plastic (PPS-GF40)

Casing parts in contact with the fluid and the atmosphere are free from paint-wetting impairment substances.

Minimum inlet pressure and temperature limits

Minimum pressure required at the pump inlet to avoid cavitation noise. The values apply up to 300 m above sea level; above that, add 0.01 bar per 100 m.

Fluid temperatureMinimum inlet pressure
Up to 70 °C0.5 bar
LimitValue
Fluid temperature+2 to +70 °C
Ambient temperature0 to +40 °C
Modbus interface

The pump connects to the building automation system via its Modbus RTU interface.

PropertyValue
InterfaceRS485 (TIA-485A), optically isolated
ProtocolModbus RTU
Baud rate4,800, 9,600, 19,200 (factory setting), 38,400, 57,600, 115,200 baud
Data format8 data bits, parity EVEN, ODD or NONE, 1 stop bit
Modbus addressSelectable from 1 to 247 (factory setting 17)
CableTwisted-pair bus cable, 0.5 mm²; terminal cross-section 1.5 mm²
Line lengthMax. 1000 m; provide surge protection for lines longer than 30 m
Line termination120 Ω (TIA-485-A, line type B)
Dimensions and installation

All dimensions in mm. The letters refer to the dimensions in the drawing.

Threaded model
Threaded model
Flanged model
Flanged model
ModelABCDEF
25-801975398180137168
30-1001975398180137168
30-1202325398180137168
40-8024270120220137168
40-10024270120220137168

Flange dimensions (mm)

Flange dimension drawing
FlangePN 6: Ø DPN 6: Ø kPN 6: holesPN 10: Ø DPN 10: Ø kPN 10: holes
DN 401301004 × Ø 141501104 × Ø 19

Permitted installation positions

Permitted installation positions for CalioTherm Pro
Permitted installation positions for CalioTherm Pro

Scope of supply

  • Pump
  • Two-part thermal insulation shell
  • Flat gaskets and washers
  • Installation and operating manual
Accessories

Pipe unions

AccessoryConnectionMaterial no.
Pipe unions, set of 2 (G 1½ union nut, insert with Rp 1 internal thread, brass)G 1½ / Rp 119075564
Pipe unions, set of 2 (G 2 union nut, insert with Rp 1¼ internal thread, brass)G 2 / Rp 1¼19075565

Source: KSB type series booklet CalioTherm Pro (1157.581/09, 17.07.2026). Also applies to Calio-Therm. The scope of supply may vary by model.

Calio Therm models

5 available options

Connection
Motor power

How to read the model name

  • 25Connection: G 1½ union
  • 80Head: 8 m
ModelConnectionHeadFlow rateMotor powerControlMaterial no.Quote
25-80 G 1½ union 8 m 11 m³/h 180 W 0-10 V, Modbus 29134853
30-100 G 2 union 10 m 12 m³/h 180 W 0-10 V, Modbus 29134854
30-120 G 2 union 12 m 15.5 m³/h 330 W 0-10 V, Modbus 29134855
40-80 DN 40 flange 8 m 21 m³/h 265 W 0-10 V, Modbus 29134849
40-100 DN 40 flange 10 m 24 m³/h 360 W 0-10 V, Modbus 29134856

5 options shown

Product documents

CalioTherm Pro

Also applies to Calio Therm

Installation and Operating ManualComing soon Type Series BookletPDF · 18 pages · 3.9 MB

Let’s choose the right Calio Therm model together.

Request a Quote