Circulator pump

Calio SI Therm

Residential pump with stainless steel casing for drinking and domestic water

The Calio SI series developed for domestic hot water circulation in homes and small commercial buildings. Its 1.4401 (AISI 316) stainless steel casing is suitable for applications in contact with drinking water. With a G 1½ union connection and 180 mm overall length, it fits easily into existing systems; available with or without display.

Connection
G 1½
Head
7 to 9.5 m
Overall length
180 mm
Available options
2
  • Suitable for drinking water
View Models

For OEM options, please get in touch with us.

Hygienic casing, hot water comfort

Calio SI Therm keeps water circulating in the domestic hot water line so hot water is available without waiting. With its corrosion-resistant stainless steel casing, it is the Calio SI series to choose for drinking water applications.

Why Calio SI Therm?

  1. 01

    Stainless Steel Casing

    1.4401 (AISI 316) stainless steel casing, suitable for drinking and domestic water circulation.

  2. 02

    With or Without Display

    The 25-70-180 with display offers proportional pressure, constant pressure and constant speed modes plus PWM or 0-10 V control; the 78 W 25-95-180 without display offers a 9.5 m head and PWM control.

  3. 03

    High-Efficiency Motor

    Low energy consumption in continuously running hot water lines thanks to high-efficiency motor technology.

  4. 04

    Easy Replacement

    Easily replaces existing pumps thanks to the G 1½ union connection and standard 180 mm overall length.

Calio SI Therm technical data

Casing material
Stainless steel (AISI 316)
Operating modes
Display models: proportional pressure (PP), constant pressure (CP), constant speed (CC), Eco modeModels without display: run on an external signal
External control
Display models: PWM and 0-10 VModels without display: PWM
Display
With and without display
Pressure rating
PN 10
Temperature class
TF 110
Energy efficiency (EEI)
≤ 0.20

Pump characteristic curves

The curves apply to Calio SI Therm 25-70-180 and 25-95-180.

Size

Speed range 800 to 3650 rpm. Each chart shows head (H, m) at the top and electrical power (P, kW) at the bottom, with flow rate (Q, m³/h) on the horizontal axis.

Calio SI 15-70 and 25-70 proportional pressure (Δp-v) curve
Proportional pressure (Δp-v)Head decreases as the flow rate falls; the recommended mode for heating circuits.
Calio SI 15-70 and 25-70 constant pressure (Δp-c) curve
Constant pressure (Δp-c)Head stays constant even when the flow rate changes; for underfloor heating and single-pipe systems.
Calio SI 15-70 and 25-70 speed control (external signal or constant speed) curve
Speed control (external signal or constant speed)Speed curves for a PWM or 0-10 V signal from a boiler or controller.

Technical details

The information in this section applies to the Calio SI Therm 25-70-180 with display.

Operating data
PropertyValue
HeadUp to 8 m
Fluid temperature-10 to +110 °C
Ambient temperature0 to +70 °C (-20 to +75 °C on request)
Operating pressureUp to 10 bar
Sound pressure levelBelow 30 dB(A)
ConnectionG 1, G 1½, G 2 (threaded)
Motor and design
  • Maintenance-free, high-efficiency wet rotor pump
  • Brushless, self-cooling permanent magnet synchronous motor
  • 1~230 V AC, 50/60 Hz; starting current 3 A
  • Enclosure IP44, insulation class F, temperature class TF 110
  • Energy efficiency index EEI ≤ 0.20 (EN 16297-3)
  • Ceramic bearings, integrated electronic motor protection
  • Electromagnetic compatibility: EN 55014-1, EN 55014-2; safety: IEC 60335-2-51
Operating modes and display
  • Operation with an external signal (PWM or 0-10 V)
  • Constant pressure (Δp-c) and proportional pressure (Δp-v) control
  • EcoMatch: automatic adjustment of the operating point (optional)
  • Speed step setting, venting function, blocked rotor release
  • The display shows flow rate, head and power input in turn; error messages appear on the display
Applications and fluids

Applications

  • Heating, ventilation and air-conditioning systems
  • Circulation systems; single-pipe and two-pipe systems
  • Underfloor heating
  • Boiler or primary circuits, hot water cylinder circuits
  • Solar thermal systems and heat pumps

Suitable fluids

  • Heating water to VDI 2035. If the glycol content is 20% or more, the operating data must be checked.
  • Clean, thin, non-aggressive, non-explosive and non-gaseous fluids free of mineral oil, solids or long fibres
  • Viscosity up to 10 mm²/s
Materials
PartCalio SI Therm
Pump casingStainless steel 1.4401 (AISI 316)
ShaftCeramic
ImpellerGlass fibre reinforced polyethersulfone (PES)
Plain bearingCeramic
Bearing plateStainless steel 1.4301
Rotor canStainless steel 1.4301
Thermal insulation shellPolypropylene
External control: PWM and 0-10 V

The pump communicates with the external control system via its integrated bidirectional PWM interface: it reports the estimated flow rate to the control system, receives the required pressure in return and adjusts its speed accordingly.

SituationPWM profile A (heating)PWM profile C (solar)
No signal connectedPump runs at maximum speedPump stops
Speed setting (modulation)5% to 90%5% to 90%
Maximum speed0% to 5%90% to 94%
Standby92% to 100%94% to 100%

Feedback from the pump to the control system: 85% pump ID, 75% blocked rotor, 20% to 70% estimated flow rate, 10% dry running.

A 0-10 V analogue signal is connected to the same terminals; as the signal rises, the speed increases linearly from 800 rpm to the maximum speed for the size.

SizeMinimum speedMaximum speed
15-50-130, 25-50-130, 25-50-180800 rpm3080 rpm
15-70-130, 25-70-130, 25-70-180800 rpm3650 rpm
15-80-130, 25-80-130, 25-80-180, 30-80-180800 rpm4000 rpm
Minimum inlet pressure

The minimum pressure required at the pump suction to prevent cavitation noise. The values apply up to 300 m above sea level; above that, add 0.01 bar for every 100 m.

Fluid temperatureMinimum inlet pressure
5 to 75 °C0.05 bar
76 to 95 °C0.4 bar
Dimensions and installation
Calio SI and Calio SI Therm dimension drawing
Dimensions in mm. H: overall length (130 or 180 mm, the last number in the model name).
Permitted installation positions
Permitted installation positions: the motor shaft must always be horizontal.
Electrical connection
Power and control cable connection
No.Connection
1Power cable (L phase, N neutral, earth; 230 V AC)
2Control cable
3PWM signal input (from the external control system to the pump) or 0-10 V
4Signal ground (PWM or 0-10 V)
5PWM signal output (from the pump to the external control system)

The pump is powered via a pre-assembled power cable with connector. Scope of supply: pump; cables are ordered as accessories.

Accessories
AccessoryLengthMaterial no.
Power cable 230 V1 m11009300
Power cable 230 V2 m11009301
Power cable 230 V3 m11009302
Control cable (PWM / 0-10 V)0.5 m11009400
Control cable (PWM / 0-10 V)1 m11009401
Control cable (PWM / 0-10 V)2 m11009402
Control cable (PWM / 0-10 V)3 m11009403
Thermal insulation shell (left)S9800214
Thermal insulation shell (right)S9800217

Source: KSB Calio SI and Calio SI Therm type series booklet (1157.57/06, 01.02.2022).

Calio SI Therm models

2 available options

Motor power
Display

How to read the model name

  • 25Connection: G 1½ union
  • 70Head: 7 m
  • 180Overall length: 180 mm
ModelConnectionHeadFlow rateOverall lengthMotor powerControlDisplayMaterial no.Quote
25-70-180 G 1½ union 7 m 3.6 m³/h 180 mm 52 W PWM and 0-10 V with display 48242089
25-95-180 G 1½ union 9.5 m 2.8 m³/h 180 mm 78 W PWM without display 50002014

2 options shown

Product documents

Calio SI Therm

Models with stainless steel casing

Installation and Operating ManualComing soon Type Series BookletPDF · 18 pages · 6.7 MB

Let’s choose the right Calio SI Therm model together.

Request a Quote

Fill in the form and our sales team will get back to you shortly.